Poly and air sealing in Kensington before the board goes on

Alberta winters put a large vapour drive from inside to outside, so the barrier belongs on the warm side of the insulation. Getting the position right matters as much as getting it sealed: a second barrier on the cold side traps moisture in the assembly with no way to dry.

Vapour Barrier Installation Kensington Edmonton

Watch vapour barrier installation jobs in Kensington Edmonton on our YouTube channel

Sealing at the electrical boxes

Every box is a hole

An outlet or switch on an exterior Kensington wall is a deliberate opening straight through the barrier.

The fix

Poly hats or airtight boxes, sealed to the sheet. Taping the poly to the front of an ordinary box does not last, because the board is fastened over it and the seal breaks. This is the single most common leak we find behind finished walls.

Kensington drywall in context

About Kensington

Kensington was annexed to the City in 1913 during a real estate boom but most development didn't occur until the 1950s.

What we see in Kensington

In Kensington the drywall work is plaster and lath repair, popcorn and stipple ceiling removal, careful patching into original surfaces. We confirm what your home actually needs on site, in writing, before anything starts.

Bathrooms, kitchens and the wet rooms

More moisture, same rules

A Kensington bathroom pushes far more vapour into the wall than a bedroom. The barrier is not different, but the consequences of a gap are larger and show up faster.

Fans and penetrations

The fan housing, the duct and any pot lights all pierce the plane in the wettest room in the house. Those are sealed rather than trimmed around, and we check that the fan actually vents outside rather than into the attic.

The rim joist and the bottom plate

Two cold junctions

In an Kensington basement the rim joist and the bottom plate against concrete are where warm air meets cold most directly. Both need sealing before insulation, not after.

Sequencing

Once the insulation and poly are on, neither can be reached without pulling the wall apart. We deal with them first, and we would rather flag a problem there at the quote than discover it behind a finished wall.

Why the warm side, and why only one

Which way the moisture moves

Through an Kensington winter, warm humid indoor air pushes outward through the assembly. A vapour barrier on the warm side stops that moisture before it reaches a cold surface where it can condense.

Two barriers is worse than one

A second barrier on the cold side traps moisture between the two with no direction to dry. It is a genuine mistake we still find in renovated walls, and it is invisible until the damage shows.

Top plates, bottom plates and the perimeter

The edges do the leaking

The continuous joints at the top and bottom of an Kensington wall are longer than every box and lap put together, and they are the easiest to seal well or badly.

What good looks like

Sealant on the plate, poly laid into it and compressed by the framing or the board above, carried around corners rather than cut and butted at every change of direction.

Renovations, and meeting an existing barrier

Continuity across old and new

In an Kensington renovation the new poly has to tie into whatever is already in the wall. A new sheet stopped at the edge of the work leaves an open seam inside the assembly.

What we look for

Whether an existing barrier is present at all, what condition it is in, and whether there is a second one somewhere that would trap moisture between the two. Older renovations quite often have both, and finding that before boarding is worth the hour it takes.

Simple, clean, on schedule — Vapour Barrier Installation in Kensington Edmonton

1

Free quote

We come out to your Kensington Edmonton property, take a real look at the vapour barrier installation, and hand you a fixed price on the spot — no guessing, no vague ballpark. Every vapour barrier installation quote in Kensington Edmonton starts with an honest, on-site assessment.

2

Book a day

We pick a day that works for your schedule and show up on time, ready to start the vapour barrier installation in Kensington Edmonton. No back-and-forth rescheduling — once it's booked, our team is there.

3

The work

We keep the dust under control and protect your Kensington Edmonton home while we finish the vapour barrier installation to a clean, paint-ready standard. Floors covered, doors sealed off, and the site left tidy at the end of every day.

4

Walk it with you

We don't pack up till you've walked the finished vapour barrier installation with us and you're happy with the result in Kensington Edmonton. If anything needs a second look, we handle it before we call the job done.

Rated by Edmonton Homeowners

Emplastrum Drywall is the vapour barrier installation contractor Kensington Edmonton trusts for repair, restoration and finishing — rated on Google by Edmonton homeowners.

Read the reviews, or leave your own after your vapour barrier installation project in Kensington Edmonton.

Read our reviews on Google

Vapour Barrier Installation Kensington Edmonton: your questions answered

Can you install the barrier if someone else did the insulation?
Yes, but we check the insulation first. A barrier over a poorly filled cavity locks the problem in, and once the board is on neither can be corrected without opening the wall.
Will this pass inspection?
It is built to what the code asks for on your permit, and we leave it visible and sequence to your inspection date rather than boarding ahead. If an inspector raises something, we want the note directly so it is fixed from the actual reason.
Does it matter where the sheet meets the ceiling and floor?
It is the whole job. Left loose at the top or bottom plate, warm air simply goes over or under a perfectly installed sheet. The junction into a vaulted ceiling is the most commonly skipped and the wettest point in the room.
Should I use poly or a smart membrane?
Most straightforward Kensington walls are fine with 6-mil poly, continuous and sealed. A variable-permeance membrane is worth it on retrofits and some basement details because it gives the assembly a drying path in both directions.
Is a bathroom done differently?
Same rules, larger consequences. A bathroom pushes far more vapour into the wall, so a gap shows up faster. The fan housing and duct are sealed rather than trimmed around, and we check the fan vents outside rather than into the attic.
Will this stop water coming through my basement wall?
No, and installing it would hide the evidence. Water coming through a wall is a drainage and waterproofing problem. Vapour control manages moisture in the air, not liquid water, and we will say so rather than board over it.
Get Your Free Drywall Quote
Tell us about your project — we’ll get right back to you, 7 days a week. Prefer to call? (403) 829-8702.
No obligation. We never share your information.
📞  Call (403) 829-8702 Free Quote
See our latest drywall projects & updates on FacebookFollow Emplastrum Drywall — Edmonton, St. Albert, Sherwood Park, Spruce Grove & Stony Plain Follow on Facebook